PLASTEC Series Blowers

Series Overview

The PLASTEC Series of fans and blowers are direct drive centrifugal fans designed specifically for exhausting fumes from highly corrosive environments. These blowers are constructed entirely from polypropylene with thick walls. A key feature is the absence of metal in the airstream, which provides maximum protection against acids and corrosion. Polypropylene is noted as having the best resistance against acids and corrosion. The units also include Hindered-Amine Light Stabilizers (HALS) for increased UV resistance.

The PLASTEC series is ideally suited for use in various industries and settings where corrosive substances or fumes are present, including:

  • Laboratories
  • Chemical plants
  • Hospitals
  • Universities & research institutes
  • Chemical processing and storage
  • Water treatment & sewage / Wastewater treatment
  • Pharmaceutical and medical facilities
  • Oil, petroleum & gas industry
  • Hemp production
  • Coastal regions
  • Maritime transport & marine applications
  • Agricultural & food processing
  • Electric vehicle manufacturing & storage

Certain models within the PLASTEC series are also available in an Explosion Resistant version, suitable for explosive atmospheres.

Models Available

The PLASTEC series includes the following direct drive forward curve polypropylene blowers:

  • Plastec 15
  • Plastec 20
  • Plastec 25
  • Plastec 30
  • Plastec 35
  • Plastec 50

These models cover 6 sizes [prior conversation].

Detailed data points are available for each model in their respective specification sheets. Key information generally includes:

  • Airflow (CFM): Max and Min Air Flow are specified for each model. For example, the Plastec 50 has models with Max Flow up to 10800 CFM and Min Flow of 800 CFM. Performance curves showing airflow vs. static pressure are available for each model.
  • Inlet/Outlet Diameter: Each model has a specified Inlet Diameter and Outlet Diameter. These are also noted as ØA (OD) and ØF (OD) in dimensional data.
    • Plastec 15: Inlet ØA(OD) 4.91 in (125 mm), Outlet ØF(OD) 4.91 in (125 mm)
    • Plastec 20: Inlet ØA(OD) 6.29 in (160 mm), Outlet ØF(OD) 6.29 in (160 mm)
    • Plastec 25: Inlet ØA(OD) 7.86 in (200 mm), Outlet ØF(OD) 7.86 in (200 mm)
    • Plastec 30: Inlet ØA(OD) 9.83 in (250 mm), Outlet ØF(OD) 9.83 in (250 mm)
    • Plastec 35: Inlet ØA(OD) 12.38 in (315 mm), Outlet ØF(OD) 12.38 in (315 mm)
    • Plastec 50: Inlet ØA(OD) 19.65 in (500 mm), Outlet ØF(OD) 23.58 in (600 mm)
  • Motor specs: Data includes Phase (Single or Three Phase), Frequency (Hz), Power (Hp), RPM, Poles, Voltage (V), Amperage (A - FLA), and Thermal Overload Protection. For example, the Plastec 15 is available with 0.33 Hp or 0.5 Hp single-phase motors or 0.33 Hp three-phase motors. The Plastec 50 is available with 5.5 Hp or 10 Hp three-phase motors, and the 10 Hp model comes with a VFD.
  • Dimensions: Detailed dimensional data (in/mm) including C, D, G, H, I, J, and K (Max Height) are provided in specification sheets for each model.
  • Weight: Weight in pounds (lbs or lb) is listed as a data point for each model. Specific weights are provided for Plastec 50 models (e.g., 256.7 lb, 255.2 lb).
  • Mounting options: While not explicitly listed as options, the Installation, Operation & Maintenance Manual illustrates a Roof Unit Assembly, suggesting roof mounting is a designed configuration, at least for some models like the Plastec 35.

Performance and Dimensions

The PLASTEC series offers a range of performance capabilities. The overall performance range is from 0.25"-12" Static Pressure (extending the previously noted 8" based on Plastec 50 data) and from 30-10800 CFM.

Performance certified is for installation type D – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Maximum fan input power is catalogued over the range.

Key Performance & Dimensional Data Summary (Selected Data Points):

Model Inlet Dia. (in / mm) Outlet Dia. (in / mm) Max Static Pressure (in. Wg) (Examples from sources) Max Air Flow (cfm) (Examples from sources) Max Height (K) (in / mm) (Examples from sources)
Plastec 15 4.91 / 125 4.91 / 125 N/A (See Curve) N/A (See Curve), Max Flow (from Model Data): 3370 12.19 / 310
Plastec 20 6.29 / 160 6.29 / 160 N/A (See Curve) N/A (See Curve), Max Flow (from Model Data): 1200 12.19-14.94 / 310-380 (depending on motor)
Plastec 25 7.86 / 200 7.86 / 200 N/A (See Curve) N/A (See Curve) 14.59-17.24 / 371-439 (depending on motor)
Plastec 30 9.83 / 250 9.83 / 250 N/A (See Curve) N/A (See Curve) 17.34 / 441 (for 0.75 & 1.5 Hp)
Plastec 35 12.38 / 315 12.38 / 315 N/A (See Curve) N/A (See Curve) 22.81-23.59 / 580-600 (depending on motor)
Plastec 50 19.65 / 500 23.58 / 600 Max Static Pressure (from Model Data): 12 Max Flow (from Model Data): 10800 29.13 / 741 (for 5.5 & 10 Hp)

Note: Specific performance curves are available for detailed selection. Dimensional data tables with measurements C, D, G, H, I, J are also available for each model.

Installation and Wiring

Installation, operation, and maintenance instructions are provided in a dedicated manual. It is essential to fully read and understand this manual before installing, using, or operating the equipment. Detailed instructions may be presented separately.

Installation, adjustment, and servicing should only be performed by qualified electrical maintenance personnel familiar with the equipment and associated hazards. Users and installers should also read "RECOMMENDED SAFETY PRACTICES FOR AIR MOVING DEVICES" published by AMCA. General precautions for electrical wiring are outlined, including warnings about potential property damage or serious injury if not followed by qualified personnel. Standard electrical data points include Phase, Frequency, Power, RPM, Voltage, Amperage, and Thermal Overload Protection.

The manual includes assembly illustrations, such as for a Roof Unit 35 Kit Assembly, showing steps like removing inlet screws, placing a roof cap, attaching brackets, attaching a motor weather cover, and installing guards.

Certifications and Compliance

The PLASTEC series follows manufacturing standards including ISO 9001-2008 (from prior conversation). Test performance procedures are conducted for PLASTEC and STORM Series according to AMCA standards.

Explosion Resistant versions of the Plastec 15, Plastec 20, Plastec 25, Plastec 30, and Plastec 35 models are available [prior conversation]. These versions are compliant with international standards:

  • NEC 500: CLASS I DIV II GROUP A,B,T4
  • NEC 505: CLASS I ZONE II AEx d GROUP IIC T4
  • ATEX: Ex II 3G Ex c GROUP IIC T4
  • European directives

PLASTEC VENTILATION PRODUCTS with Explosion Resistant certification are certified only for ZONE II GAZ. Additives are used in the polypropylene of these versions to reduce the risk of creating an electrical charge [prior conversation]. The sources also display logos for NEC, ATEX, and IEC.

Discharge Configurations

The PLASTEC blowers offer flexible discharge orientations. The mechanical data sheets for each model illustrate various available discharge angles and clockwise (CW) or counter-clockwise (CCW) rotation options. Orientations shown include angles around the full 360 degrees, typically in 45 or 90-degree increments (e.g., 360, 45, 90, 135, 180, 225, 270, 315 degrees).

Compatible Applications

The PLASTEC series is suitable for a wide range of demanding applications due to its corrosion-resistant construction and availability of explosion-resistant options. Common applications include:

  • Laboratory hood extraction [implied by use in laboratories 1, 2, 3, 4, 16, 20, 24, 28, 32, 35]
  • Chemical processing and storage ventilation
  • Exhausting fumes from highly corrosive environments in general
  • Ventilation in hospitals, universities, and research institutes handling corrosive substances
  • Applications in water and wastewater treatment facilities
  • Ventilation in pharmaceutical and medical facilities
  • Use in oil, petroleum, gas, and hemp production facilities
  • Ventilation in coastal regions and maritime applications where saltwater corrosion is a concern
  • Applications in agricultural and food processing environments which may involve corrosive cleaning agents or materials
  • Ventilation in electric vehicle manufacturing and storage areas
  • Applications requiring connection to scrubbers [prior conversation].

The Plastec 15, 20, 25, 30, and 35 Explosion Resistant versions are suitable for hazardous locations classified as ZONE II GAZ. The Plastec 50 with its included VFD can also meet explosive resistant applications.